dc.contributor.author | Özcan, Erhan Cahit | |
dc.contributor.author | Gül, Mehmet | |
dc.contributor.author | Dündar, Serkan | |
dc.contributor.author | Bozoğlan, Alihan | |
dc.contributor.author | Karasu, Necmettin | |
dc.contributor.author | Bal, Ali | |
dc.contributor.author | Güneş, Nedim | |
dc.contributor.author | Bingül, Muhammet Bahattin | |
dc.date.accessioned | 2022-04-26T13:35:29Z | |
dc.date.available | 2022-04-26T13:35:29Z | |
dc.date.issued | 17.07.2021 | en_US |
dc.identifier.citation | Ozcan, E. C., Gul, M., Dundar, S., Bozoglan, A., Karasu, N., Bal, A., ... & Bingul, M. B. (2021). Effects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants. Journal of Oral Biology and Craniofacial Research, 11(4), 524-528. | en_US |
dc.identifier.issn | 2212-4268 | |
dc.identifier.uri | https://doi.org/10.1016/j.jobcr.2021.07.008 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12933/836 | |
dc.description.abstract | Objective: Researchs of the effects of ankaferd blood stopper (ABS) on bone healing metabolism have revealed that
it affects bone regeneration positively. The exact mechanism by which this positive effect on bone tissue metabolism is not known. The aim of this study is to biomechanic and biochemical analysis of the effects of the local
ABS application on osseointegration of 3 different surfaced titanium implants.
Material & Methods: Spraque dawley rats were divided machined surfaced (MS) (n ¼ 10), sandblasted and large
acid grid (SLA) (n ¼ 10) and resorbable blast material (RBM) (n ¼ 10) surfaced implants. ABS applied locally
during the surgical application of the titanium implant before insertion in bone sockets. After 4 weeks experimental period the rats sacrificed and implants with surrounding bone tissues were removed to reverse torque
analysis (Newton), blood samples collected to biochemical analysis (ALP, calcium, P)
Results: Biomechanic bone implant contact ratio detected higher in SLA surfaced implants compared with the RBM
and controls (P < 0,05). Phosphor levels detected lower in RBM implant group compared with the controls and
SLA (P < 0,05). Additionally; phosphor levels detected highly in controls compared with the RBM implants.
Conclusion: According the biomechanical parameters ABS may be more effective in SLA and RBM surfaced implants when locally applied. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.isversionof | 10.1016/j.jobcr.2021.07.008 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Ankaferd blood stopper | en_US |
dc.subject | Osseintegration | en_US |
dc.subject | Bone implant contact | en_US |
dc.subject | Implant surfaces | en_US |
dc.subject | Biomechanic | en_US |
dc.title | Effects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants | en_US |
dc.type | article | en_US |
dc.authorid | 0000-0001-6513-0226 | en_US |
dc.authorid | 0000-0002-5721-8778 | en_US |
dc.authorid | 0000-0003-3944-1957 | en_US |
dc.authorid | 0000-0003-3420-5816 | en_US |
dc.authorid | 0000-0003-0388-5767 | en_US |
dc.authorid | 0000-0001-5750-4224 | en_US |
dc.authorid | 0000-0001-7160-1899 | en_US |
dc.authorid | 0000-0002-6581-2363 | en_US |
dc.department | AFSÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Plastik Rekonstrüktif ve Estetik Cerrahi | en_US |
dc.contributor.institutionauthor | Karasu, Necmettin | |
dc.identifier.volume | 11 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 524 | en_US |
dc.identifier.endpage | 528 | en_US |
dc.relation.journal | Journal of Oral Biology and Craniofacial Research | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |