Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDeste Gökay, Gonca
dc.contributor.authorGökçimen, Gülsüm
dc.contributor.authorDurkan, Rukiye
dc.date.accessioned2022-06-14T12:10:41Z
dc.date.available2022-06-14T12:10:41Z
dc.date.issued2021en_US
dc.identifier.citationGÖKAY, G. D., GÖKÇİMEN, G., & DURKAN, R. EVALUATION OF BIOMECHANICAL EFFECTS OF PROSTHETIC COMPONENTS WITH DIFFERENT MATERIALS ON THE ABUTMENT SCREW. Cumhuriyet Dental Journal, 24(4), 337-345.en_US
dc.identifier.issn2146-2852
dc.identifier.urihttps://doi.org/10.7126/cumudj.982237
dc.identifier.urihttps://hdl.handle.net/20.500.12933/1162
dc.description.abstractObjectives: The purpose of this study was to evaluate the effects of different resin-based and ceramic superstructure materials and two different abutment types on the stress distribution of the abutment screw using the three-dimensional finite element stress analysis method. Materials and Methods: A three dimensional implant, abutment (zirconia and titanium), abutment screw, crown (zirconia reinforced lithium silicate, lithium disilicate, polymer-infiltrated resin ceramic, and PEEK), and alveolar bone were designed using Rhinoceros 3D modeling software and VRMesh Studio software and combined to form 8 simulations. On the models prepared, loading was made on the lingual tubercule of the maxillary right first premolar crown at an angle of 30° with 150 N force obliquely in the buccolingual direction. The von Mises values obtained from the abutment screw were compared according to the types of abutment and crown materials. Results: The von Mises stress values in the abutment screw were higher in the models using a titanium abutment abutment (on average 1336.24 MPa), and the lower stress values were obtained in the models using a zirconia abutment (on average 964.26 MPa). When the prosthetic material used was changed, no apparent difference was observed in the stress values on the abutment screw. Conclusions: Considering that the abutment screw is the weakest link of the implant system, zirconia abutments can be used reliably in the maxillary first premolar region where aesthetic expectations are high.en_US
dc.language.isoengen_US
dc.publisherCumhuriyet University Faculty of Dentistryen_US
dc.relation.isversionof10.7126/cumudj.982237en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental abutmentsen_US
dc.subjectDental stress analysisen_US
dc.subjectGlass ceramicsen_US
dc.titleEVALUATION OF BIOMECHANICAL EFFECTS OF PROSTHETIC COMPONENTS WITH DIFFERENT MATERIALS ON THE ABUTMENT SCREWen_US
dc.typearticleen_US
dc.authorid0000-0002-2336-4929en_US
dc.departmentAFSÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorGökçimen, Gülsüm
dc.identifier.volume24en_US
dc.identifier.issue4en_US
dc.identifier.startpage337en_US
dc.identifier.endpage345en_US
dc.relation.journalCumhuriyet Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster