dc.contributor.author | Uygun, Ahmet Demirhan | |
dc.contributor.author | Ünal, Mehmet | |
dc.contributor.author | Falakaloğlu, Seda | |
dc.contributor.author | Güven, Yahya | |
dc.date.accessioned | 2021-05-05T22:14:13Z | |
dc.date.available | 2021-05-05T22:14:13Z | |
dc.date.issued | 2020 | |
dc.identifier.issn | 1119-3077 | |
dc.identifier.uri | https://doi.org/10.4103/njcp.njcp_343_19 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12933/369 | |
dc.description | WOS:000507341100007 | en_US |
dc.description | PubMed: 31929205 | en_US |
dc.description.abstract | Objective: This in vitro study aimed to compare the cyclic fatigue resistance of HyFlex EDM (HEDM), Vortex Blue (VB), ProTaper Gold (PG), and OneCurve (OC) nickel-titanium (NiTi) instruments. Materials and Methods: About 12 HEDM (25/.similar to), 12 VB (25/.06), 12 PG (25/.08), and 12 degrees C (25/.06) instruments were included in this study. All the instruments were tested with a 60 degrees angle of curvature and a 3-mm radius of curvature. All the instruments were utilized until fracture occurred, and then the number of cycles to failure (NCF) was calculated. The data were analyzed statistically using Kruskal-Wallis H and Mann-Whitney U-tests. The statistical significance level was set at P < 0.05. Results: HEDM instruments had the highest cyclic fatigue resistance among all the other instruments (P < 0.05). The OC instruments had a significantly higher fatigue resistance than the PG and VB instruments (P < 0.05); however, there was no significant difference between PG and VB instruments in the NCF (P > 0.05). Conclusion: Within the limitations of this in vitro study, it was found that the cyclic fatigue resistance was higher for the HEDM instruments than for the VB, PG, and OC instruments. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Wolters Kluwer Medknow Publications | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cyclic fatigue resistance | en_US |
dc.subject | heat-treated NiTi instruments | en_US |
dc.subject | HyFlex EDM | en_US |
dc.subject | OneCurve | en_US |
dc.title | Comparison of the cyclic fatigue resistance of hyflex EDM, vortex blue, protaper gold, and onecurve nickel-Titanium instruments | en_US |
dc.type | article | en_US |
dc.department | AFSÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü | en_US |
dc.contributor.institutionauthor | Uygun, Ahmet Demirhan | |
dc.contributor.institutionauthor | Ünal, Mehmet | |
dc.contributor.institutionauthor | Falakaloğlu, Seda | |
dc.contributor.institutionauthor | Güven, Yahya | |
dc.identifier.doi | 10.4103/njcp.njcp_343_19 | |
dc.identifier.volume | 23 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 41 | en_US |
dc.identifier.endpage | 45 | en_US |
dc.relation.journal | Nigerian Journal Of Clinical Practice | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |