Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorUygun, Ahmet Demirhan
dc.contributor.authorÜnal, Mehmet
dc.contributor.authorFalakaloğlu, Seda
dc.contributor.authorGüven, Yahya
dc.date.accessioned2021-05-05T22:14:13Z
dc.date.available2021-05-05T22:14:13Z
dc.date.issued2020
dc.identifier.issn1119-3077
dc.identifier.urihttps://doi.org/10.4103/njcp.njcp_343_19
dc.identifier.urihttps://hdl.handle.net/20.500.12933/369
dc.descriptionWOS:000507341100007en_US
dc.descriptionPubMed: 31929205en_US
dc.description.abstractObjective: This in vitro study aimed to compare the cyclic fatigue resistance of HyFlex EDM (HEDM), Vortex Blue (VB), ProTaper Gold (PG), and OneCurve (OC) nickel-titanium (NiTi) instruments. Materials and Methods: About 12 HEDM (25/.similar to), 12 VB (25/.06), 12 PG (25/.08), and 12 degrees C (25/.06) instruments were included in this study. All the instruments were tested with a 60 degrees angle of curvature and a 3-mm radius of curvature. All the instruments were utilized until fracture occurred, and then the number of cycles to failure (NCF) was calculated. The data were analyzed statistically using Kruskal-Wallis H and Mann-Whitney U-tests. The statistical significance level was set at P < 0.05. Results: HEDM instruments had the highest cyclic fatigue resistance among all the other instruments (P < 0.05). The OC instruments had a significantly higher fatigue resistance than the PG and VB instruments (P < 0.05); however, there was no significant difference between PG and VB instruments in the NCF (P > 0.05). Conclusion: Within the limitations of this in vitro study, it was found that the cyclic fatigue resistance was higher for the HEDM instruments than for the VB, PG, and OC instruments.en_US
dc.language.isoengen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCyclic fatigue resistanceen_US
dc.subjectheat-treated NiTi instrumentsen_US
dc.subjectHyFlex EDMen_US
dc.subjectOneCurveen_US
dc.titleComparison of the cyclic fatigue resistance of hyflex EDM, vortex blue, protaper gold, and onecurve nickel-Titanium instrumentsen_US
dc.typearticleen_US
dc.departmentAFSÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorUygun, Ahmet Demirhan
dc.contributor.institutionauthorÜnal, Mehmet
dc.contributor.institutionauthorFalakaloğlu, Seda
dc.contributor.institutionauthorGüven, Yahya
dc.identifier.doi10.4103/njcp.njcp_343_19
dc.identifier.volume23en_US
dc.identifier.issue1en_US
dc.identifier.startpage41en_US
dc.identifier.endpage45en_US
dc.relation.journalNigerian Journal Of Clinical Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster