Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorTopal, Burcu Gucyetmez
dc.contributor.authorÜnal, Mehmet
dc.contributor.authorKula, Ayşenur
dc.contributor.authorAkgül, Esra Nur
dc.date.accessioned2025-12-28T16:54:01Z
dc.date.available2025-12-28T16:54:01Z
dc.date.issued2025
dc.identifier.issn1302-5805
dc.identifier.issn2146-2852
dc.identifier.urihttps://doi.org/10.7126/cumudj.1632951
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1347163
dc.identifier.urihttps://hdl.handle.net/20.500.12933/3283
dc.description.abstractObjectives: The study’s objective of this study was to evaluate the surface microhardness of different colored flowable composites cured at 20 and 40 seconds with an LED light unit. Materials and Methods: In present study, flowable composites (Rainbow Flow, PPH CERKAMED, Poland) in purple, blue, orange, pink, green, and yellow were used, and the samples were cured in 5x2 mm disc moulds using a VALO™ LED unit (Ultradent, U.S.A) for 20 and 40 seconds. A load of 100 grams was applied to the samples for 10 seconds using a microhardness tester (Shimadzu Micro Hardness Tester HMV-2, Japan).The average Vickers hardness values was calculated.The findings were analysed statistically (IBM SPSS®, U.S.A). Results: A statistically significant difference was found in the microhardness of composites with two curing times according to their colors (p < 0.001). The microhardness of the purple flowable composite was found to be numerically higher than the other colors when cured for both 20 and 40 seconds.At a curing time of 40 seconds,the microharness value of the purple and blue compositews were found to be statistically higher than that of the pink and orange composites (p < 0.05).When comparing microhardness values according to curing times,the microhardness values of all colors in the groups cured for 40 seconds were found to be statistically higher than those in the groups cured for 20 seconds (p < 0.05). Conclusions: In summary, it was determined that the microhardness exhibited an increase with an increase in curing time for all colors. However, the microhardness values of the dark-colored flowable composites were higher irrespective of curing time.Further studies are necessary to investigate the physical properties of colored flowable composites. Such studies will allow for the accurate recommendation of curing times for colored composites.
dc.language.isoen
dc.relation.ispartofCumhuriyet Dental Journal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectColored flowable composites
dc.subjectcuring times
dc.subjectmicrohardness
dc.subjectLED light
dc.titleEvaluation of the Microhardness of Six Different Colored Flowable Composites Cured at Different Times with LED Light Device
dc.typeArticle
dc.departmentAFYONKARAHİSAR SAĞLIK BİLİMLERİ ÜNİVERSİTESİ,Afyonkarahisar Sağlık Bilimleri Üniversitesi,Afyonkarahisar Sağlık Bilimleri Üniversitesi,Afyonkarahisar Sağlık Bilimleri Üniversitesi
dc.identifier.doi10.7126/cumudj.1632951
dc.identifier.volume28
dc.identifier.issue3
dc.identifier.startpage334
dc.identifier.endpage340
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.department-tempAfyonkarahisar Sağlık Bilimleri Üniversitesi
dc.identifier.trdizinid1347163
dc.indekslendigikaynakTR-Dizin
dc.snmzKA_TR-Dizin_20251227


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster