dc.description.abstractIntroduction: The aim was to evaluate the polymerization properties of bulk-fill composite resins in terms of the degree of conversion (%DC), Vickers hardness (HV). SonicFill (SF, Kerr, CA, USA), Tetric Evo Ceram Bulk-Fill (TECBF, Ivoclar Vivadent Schaan, Lichtenstein), and X-trafil (XTF, Voco GmbH, Cuxhaven, Germany) were investigated. Methods: The samples prepared from composites (n = 10) were polymerized via three different curing modes (standard mode: 20 s, high-power mode: 12 s, extra power mode: 6 s) using a polywave LED. %DC was determined by FTIR-ATR-spectroscopy. HV was measured at the top and bottom of the specimens. Data were analyzed by two way ANOVA, and Bonferroni’s post-hoc respectively (?=0.05). Results: Except TECBF (%41.10 ± 3.1) in three different curing modes, all materials showed no significant inferior %DC. In all curing modes, the highest hardness ratio was found in XTF (0.84 ± 0.03 GPa), and the lowest hardness ratio was found in the TECBF (0.78 ± 0.02GPa). In the cases where the extra power mode of the Valo Led was applied, the lowest degree of conversion and hardness were also measured. Conclusion: It has been observed that the examined properties of some tested materials change with the curing time and power of the light and however, the results are dependent on the material. Extra power mode of the Valo Led negatively affected high viscosity bulk-fill composites in terms of their polymerization properties. © 2021, Mashhad University of Medical Sciences. All rights reserved.
dc.language.isoen
dc.publisherMashhad University of Medical Sciences
dc.relation.ispartofJournal of Dental Materials and Techniques
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBulk-Fill
dc.subjectDegree of Conversion
dc.subjectLight Curing
dc.subjectResin Composite
dc.subjectVickers Hardness
dc.titleEvaluation of the Polymerization Properties of Bulk-Fill Composite Resins
dc.typeArticle
dc.departmentAfyonkarahisar Sağlık Bilimleri Üniversitesi
dc.identifier.doi10.22038/JDMT.2021.57660.1443
dc.identifier.volume10
dc.identifier.issue3
dc.identifier.startpage164
dc.identifier.endpage172
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.department-tempAltinok-Uygun, Latife, Department of Restorative Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Afyonkarahisar, Turkey; Akgül, Nilgün, Department of Restorative Dentistry, Pamukkale Üniversitesi, Denizli, Denizli, Turkey
dc.identifier.scopus2-s2.0-85186452867
dc.identifier.scopusqualityN/A
dc.indekslendigikaynakScopus
dc.snmzKA_Scopus_20251227


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record