Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorFalakalo?lu, Seda
dc.contributor.authorUygun, Ahmet Demirhan
dc.date.accessioned2025-12-28T16:50:23Z
dc.date.available2025-12-28T16:50:23Z
dc.date.issued2021
dc.identifier.issn23224150
dc.identifier.urihttps://doi.org/10.22038/JDMT.2021.54739.1415
dc.identifier.urihttps://hdl.handle.net/20.500.12933/2993
dc.description.abstractIntroduction: This study was conducted to compare the cyclic fatigue (CF) resistance of One G, WaveOne Gold Glider, T-Endo MUST tg, One G and VDW.ROTATE nickel-titanium (NiTi) glide path (GP) instruments in a simulated canal of 900 and a 3-mm radius canals at root canal temperature. Methods: Sixty NiTi files were used for the fatigue testing in stainless steel canals compatible with instrument sizes until fracture occurred (n=15): One G (#14/.03), WaveOne Gold Glider (#15/.02), T-Endo MUST tg (#13/.04), VDW.ROTATE (#15/.04), The number of cycles to fracture (NCF) was calculated for each instrument, and the lengths of the detached fragments (LDF) were measured. Data were statistically analyzed using the Kruskal–Wallis analysis and Mann-Whitney U tests at the %95 confidence level. Results: There were significant differences in the CF resistance among the groups (P < 0.05), the highest to lowest NCF values of the files as follows: T-Endo MUST tg, WaveOne Gold Glider, VDW.ROTATE, and One G. There was no significant difference within LDF among the groups P> 0.05). Conclusion: The T-Endo MUST tg files had the highest and the One G files had the lowest CF resistance in a simulated canal of 900 and 3-mm radius canals at root canal temperature. © 2021, Mashhad University of Medical Sciences. All rights reserved.
dc.language.isoen
dc.publisherMashhad University of Medical Sciences
dc.relation.ispartofJournal of Dental Materials and Techniques
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCyclic fatigue
dc.subjectGlide path
dc.subjectOne G
dc.subjectT-Endo MUST
dc.subjectVDW.ROTATE
dc.subjectWaveOne Gold Glider
dc.titleCyclic Fatigue Resistance of One G, WaveOne Gold Glider, T-Endo MUST and VDW.ROTATE Glide Path Instruments at Root Canal Temperature
dc.typeArticle
dc.departmentAfyonkarahisar Sağlık Bilimleri Üniversitesi
dc.identifier.doi10.22038/JDMT.2021.54739.1415
dc.identifier.volume10
dc.identifier.issue4
dc.identifier.startpage193
dc.identifier.endpage197
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.department-tempFalakalo?lu, Seda, Department of Endodontics, Afyonkarahisar Health Sciences University, Afyonkarahisar, Afyonkarahisar, Turkey; Uygun, Ahmet Demirhan, Department of Endodontics, Afyonkarahisar Health Sciences University, Afyonkarahisar, Afyonkarahisar, Turkey
dc.identifier.scopus2-s2.0-85186397487
dc.identifier.scopusqualityN/A
dc.indekslendigikaynakScopus
dc.snmzKA_Scopus_20251227


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.