Advanced Search

Show simple item record

dc.contributor.authorÖzden, Safa
dc.contributor.authorKayacan, Muhammed Esad
dc.contributor.authorSalmanpour, Farhad
dc.contributor.authorCamcı, Hasan
dc.contributor.authorYalçin, Bekir
dc.date.accessioned2025-12-28T16:50:21Z
dc.date.available2025-12-28T16:50:21Z
dc.date.issued2025
dc.identifier.issn00223913
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2025.09.010
dc.identifier.urihttps://hdl.handle.net/20.500.12933/2954
dc.description.abstractStatement of problem: Cobalt chromium (Co-Cr) frameworks for complete arch implant-supported fixed dental prostheses may be excessively heavy in patients with increased occlusal vertical dimension. This limitation necessitates consideration of lower density materials, which may substantially increase treatment costs. Purpose: The purpose of this study was to investigate the effects of topology optimization on the biomechanical behavior and weight reduction of Co-Cr frameworks used in complete arch implant-supported fixed dental prostheses. Material and methods: Different occlusogingival heights (10 mm and 14 mm) of complete arch implant-supported fixed dental prosthesis frameworks were virtually modeled using a dental computer-aided design (CAD) software program. For each height, 4 lattice types (Schwarz, Gyroid, Diamond, and Neovius) and 2 different maximum lattice thicknesses (2 and 3 mm) were designed. Subsequently, topology optimization was applied to each framework configuration. A total of 16 framework designs were generated, while 2 solid, nonoptimized frameworks without lattice structures were used as controls. In all optimized designs, vertical occlusal loads of 200 N were applied to the canine, premolar, and molar (cantilever) regions. Finite element analysis (FEA) was conducted for all designs to assess von Mises stress (MPa), maximum displacement (?m), reaction force (N), and weight reduction (%). Statistical analyses were performed with 1-way ANOVA and the t test (?=.05). Results: Topology-optimized lattice frameworks achieved up to 51.2% weight reduction without exceeding the material's yield strength. The occlusogingival height of the framework significantly affected von Mises stress, displacement, and reaction force values (P<.05). The Gyroid lattice demonstrated optimal performance in terms of weight reduction (P<.001). All stress and displacement values remained within the physiological tolerance limits of the supporting structures. Conclusions: Co-Cr frameworks can be significantly reduced in weight through topology optimization without compromising their mechanical integrity. The lattice geometry and the occlusogingival height of the framework are critical factors contributing to successful optimization. © 2025 Editorial Council for The Journal of Prosthetic Dentistry
dc.description.sponsorshipSağlık Bilimleri Üniversitesi, SBU; Afyon Kocatepe Üniversitesi
dc.language.isoen
dc.publisherElsevier Inc.
dc.relation.ispartofJournal of Prosthetic Dentistry
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.titleTopology design and structural optimization of Co-Cr frameworks for implant-supported prostheses
dc.typeArticle
dc.departmentAfyonkarahisar Sağlık Bilimleri Üniversitesi
dc.identifier.doi10.1016/j.prosdent.2025.09.010
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.department-tempÖzden, Safa, Department of Prosthodontics, Afyonkarahisar Health Sciences University, Afyonkarahisar, Afyonkarahisar, Turkey; Kayacan, Muhammed Esad, PhD in Mechanical Engineering, University of Nottingham, Nottingham, Nottinghamshire, United Kingdom; Salmanpour, Farhad, Department of Orthodontics, Afyonkarahisar Health Sciences University, Afyonkarahisar, Afyonkarahisar, Turkey; Camcı, Hasan, Department of Orthodontics, Afyonkarahisar Health Sciences University, Afyonkarahisar, Afyonkarahisar, Turkey; Yalçin, Bekir, Department of Mechanical Engineering, Afyon Kocatepe Üniversitesi, Afyonkarahisar, Afyonkarahisar, Turkey
dc.identifier.scopus2-s2.0-105017152564
dc.identifier.scopusqualityQ1
dc.indekslendigikaynakScopus
dc.snmzKA_Scopus_20251227


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record