Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorOzata, Merve Yeniceri
dc.contributor.authorFalakaloglu, Seda
dc.contributor.authorKaya, Sadullah
dc.date.accessioned2025-12-28T16:41:11Z
dc.date.available2025-12-28T16:41:11Z
dc.date.issued2022
dc.identifier.issn2356-3664
dc.identifier.issn2356-3656
dc.identifier.urihttps://doi.org/10.7454/msk.v26i1.1334
dc.identifier.urihttps://hdl.handle.net/20.500.12933/2846
dc.description.abstractBackground: One of the significant stages during endodontic procedures is determining the correct working length (WL). This study aimed to evaluate the accuracy of four electronic apex locators (EALs) (Root ZX mini, Raypex 6, Propex Pixi, and E-Pex Pro) and cone-beam computed tomography (CBCT) and radiographic measurement in determining the actual WL (A-WL). Methods: Thirty extracted single- root mandibular premolars were selected and flattened at the crown. The WL was determined by advancing the #15 K file until its tip was visible from the apical, and the A-WL was established by subtracting 0.5 mm from this length. The WL was also determined using periapical radiography, four EALs, and CBCT. The differences in all measurements were compared with the A-WL. The data were statistically analyzed using one-way analysis of variance (Welch) and Tamhane's test. The significance level was set at p < 0.05. Results: Compared with other measurement methods, CBCT gave shorter values than the A-WL, and this finding was statistically significant compared with those of the PR and Propex Pixi groups (p = 0.009) (p = 0.024). No significant difference was observed between the other groups (p > 0.05) except the CBCT group (p < 0.05). Conclusions: Root ZX mini and Raypex 6 made measurements close to the A-WL.
dc.language.isoen
dc.publisherUniv Indonesia
dc.relation.ispartofMakara Journal of Health Research
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComputed-Tomography
dc.subjectTeeth
dc.subjectReliability
dc.subjectSize
dc.titleComparison of the Accuracies of CBCT, Radiography, and Four Electronic Apex Locators in Working Length Determination
dc.typeArticle
dc.departmentAfyonkarahisar Sağlık Bilimleri Üniversitesi
dc.identifier.doi10.7454/msk.v26i1.1334
dc.identifier.volume26
dc.identifier.issue1
dc.identifier.startpage61
dc.identifier.endpage66
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.department-temp[Ozata, Merve Yeniceri; Kaya, Sadullah] Dicle Univ, Fac Dent, Dept Endodont, TR-21280 Diyarbakir, Turkey; [Falakaloglu, Seda] Afyonkarahisar Hlth Sci Univ, Fac Dent, Dept Endodont, TR-03200 Afyon, Turkey
dc.identifier.wosWOS:000899699700009
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.snmzKA_WoS_20251227


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster