dc.description.abstractObjective The aim of this study was to investigate temperature and time variations during root-end resection. Material and methods Sixty human premolars were selected. The root canals were enlarged up to ProTaper X3 rotary instrument. A thermocouple was placed into the root canal 1 mm behind the resection line. The teeth were randomly divided into six groups according to the apical resection method: steel bur, tungsten carbide bur, Lindeman bur, diamond bur, laser and ultrasonic surgical piezo with a diamond tip. The root ends were resected 3 mm away from the root apex. The temperature of the root dentine during resection was recorded as maximum temperature, mean temperature and temperature change. The time required for apicectomy was recorded for each group. The Kruskal-Wallis method was used to analyse the differences between temperature changes during apical resections. The significance level was set at 5%. Results There was no significant difference between bur groups in terms of temperature increase. The maximum temperature in piezo surgery was significantly higher than the Lindeman, tungsten and steel burs (p < .001). In addition, the maximum temperature in laser surgery was higher than the Lindeman bur (p < .05). An increase in the temperature was mostly seen in piezo surgery and the least temperature change occurred in the Lindeman bur. Mean time stayed under 1 min in each group. Conclusions Although piezo caused the highest temperature increase, the measured temperature increase was within physiological limits in all tested techniques.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectApical resectionen_US
dc.subjecttemperature changeen_US
dc.subjectthermocoupleen_US
dc.subjectlaser surgeryen_US
dc.subjectpiezo surgeryen_US
dc.titleTemperature and time variations during apical resectionen_US
dc.typearticleen_US
dc.departmentAFSÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorEkici, Ömer
dc.contributor.institutionauthorKanık, Özgür
dc.identifier.doi10.1080/00016357.2020.1850855
dc.identifier.volume79en_US
dc.identifier.issue2en_US
dc.identifier.startpage156en_US
dc.identifier.endpage160en_US
dc.relation.journalActa Odontologica Scandinavicaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster