Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorErcan, Mujgan
dc.contributor.authorOguz, Esra Firat
dc.contributor.authorOzcan, Mehmet
dc.contributor.authorAlp, Hamit Hakan
dc.date.accessioned2025-12-28T16:39:59Z
dc.date.available2025-12-28T16:39:59Z
dc.date.issued2026
dc.identifier.issn0009-8981
dc.identifier.issn1873-3492
dc.identifier.urihttps://doi.org/10.1016/j.cca.2025.120545
dc.identifier.urihttps://hdl.handle.net/20.500.12933/2298
dc.description.abstractSerum light immunoglobulin chains (LCs) are critical biomarkers for the diagnosis, prognosis, and treatment response monitoring in monoclonal plasma cell dyscrasias. Robust performance standards based on biological variation (BV) data are essential for optimizing patient care. This study aimed to provide updated BV estimates for serum free LCs (kappa and lambda) as well as their kappa/lambda LC ratio. Serum samples from 25 healthy volunteers (10 men, 15 women) were collected weekly over approximately 9 weeks. Serum free LCs were measured in duplicate using the Roche Cobas c501 analyzer. BV estimates with 95 % confidence intervals were calculated using coefficient of variation (CV) in ANOVA for the entire group and by sex, following assessments for outliers, normality, steadystate conditions, and variance homogeneity. The within-subject BV (CVI) estimates were 9.2 %, 8.6 %, 6.6 % for free kappa, free lambda, free kappa/lambda ratio, respectively. The between-subject BV (CVG) estimates were 24.6 %, 26.6 %, and 17.5 %for free kappa, free lambda and free kappa/lambda ratio, respectively. No significant sex differences were observed for CVI with the exception of free kappa and free kappa/lambda ratio or CVG in serum free LCs and their ratio. Free LCs and their kappa/lambda ratio exhibited marked individuality. Analytical performance specifications (APSs) for desirable imprecision and bias ranged 3.9 %-5.4 %, 4.3 %-5.8 % and 2.9 %-4.6 % for free kappa, free lambda and free kappa/ lambda ratio, respectively. This study provides updated, well-characterized BV estimates for serum free (kappa and lambda) and free kappa/lambda ratio, providing essential data to define APSs. The individuality of kappa and lambda underscores the importance of prioritizing reference change values over traditional reference intervals for improved diagnosis and monitoring in clinical practice.
dc.description.sponsorshipResearch Fund of the Afyonkarahisar Health Sciences University [22.KARIYER.007]
dc.description.sponsorshipThis study was funded by the Research Fund of the Afyonkarahisar Health Sciences University, Project number: 22.KARIYER.007.
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofClinica Chimica Acta
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectSerum free light immunoglobulin chains
dc.subjectBiological variation
dc.subjectAnalytical performance specifications
dc.titleWithin-and Between-Subject biological variation estimates of serum free light immunoglobulin chains in healthy individuals in Turkey
dc.typeArticle
dc.departmentAfyonkarahisar Sağlık Bilimleri Üniversitesi
dc.identifier.doi10.1016/j.cca.2025.120545
dc.identifier.volume578
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.department-temp[Ercan, Mujgan] Afyonkarahisar Hlth Sci Univ, Dept Med Biochem, Afyonkarahisar, Turkiye; [Oguz, Esra Firat] Ankara Bilkent City Hosp, Dept Med Biochem, Ankara, Turkiye; [Ozcan, Mehmet] Zonguldak Bulent Ecevit Univ, Dept Med Biochem, Zonguldak, Turkiye; [Alp, Hamit Hakan] Van Yuzuncu Yil Univ, Dept Med Biochem, Van, Turkiye
dc.identifier.pmid40784632
dc.identifier.scopus2-s2.0-105012832739
dc.identifier.scopusqualityQ2
dc.identifier.wosWOS:001554888300003
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.snmzKA_WoS_20251227


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster