| dc.contributor.advisor | Uygun, Ahmet Demirhan | |
| dc.contributor.author | Kalender, Latif Furkan | |
| dc.date.accessioned | 2025-12-27T20:05:48Z | |
| dc.date.available | 2025-12-27T20:05:48Z | |
| dc.date.issued | 2025 | |
| dc.identifier.uri | https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=ftqJzTasnJUH9hg-S5861rhajKkPAAqqZF00XFowMG8xlrMW_M3J4wzN-ThXw0Cp | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12933/1885 | |
| dc.description.abstract | Amaç: Bu çalışmanın amacı, farklı ısıl işlem protokolleriyle üretilmiş iki nikel-titanyum (NiTi) eğe sisteminin – Scope UniGold ve Scope UniBlue – döngüsel yorgunluk dayanımı ve yüzey pürüzlülüğü üzerindeki etkilerini karşılaştırmalı olarak değerlendirmektir. Ayrıca, kullanım sayısının ve sterilizasyonun bu parametreler üzerindeki etkileri de araştırılmıştır. Yöntem: Toplamda 120 eğenin, 96 adeti Scope UniGold ve Scope UniBlue sistemlerine ait olmak üzere dört gruba(n=12) (kullanılmamış, 1, 2 ve 3 kez kullanılmış) ayrılmıştır. Eğe sistemleri, 90° eğimli paslanmaz çelik kanallar içinde 37°C sıcaklıkta döngüsel yorgunluk testine tabi tutulmuştur. Ayrıca, geri kalan 24 tanesi yüzey pürüzlülüğü değerlendirmesi için 4 gruba bölünmüş (n=12) ve temaslı profilometre ile SA (aritmetik ortalama pürüzlülük) ve SZ (maksimum tepe-çukur yüksekliği) ölçümleri yapılmıştır. İstatistiksel analizlerde ANOVA, Mann-Whitney U ve Kruskal-Wallis testleri kullanılmıştır. Bulgular: Döngüsel yorgunluk testinde, Scope UniBlue eğelerinin Scope UniGold eğelerine kıyasla anlamlı derecede daha yüksek dayanım gösterdiği belirlenmiştir (p<0,001). Kullanım sayısı arttıkça her iki sistemde de yorgunluk direnci azalmıştır. Yüzey pürüzlülüğü sonuçlarına göre, kullanım sayısına bağlı olarak pürüzlülük değerlerinde belirgin artış gözlenmiştir. Özellikle Scope UniGold eğeleri, ikinci ve üçüncü kullanım sonrası daha yüksek pürüzlülük değerleri sergilemiştir. Sonuç: Scope UniBlue sisteminin, daha yüksek martensitik faz içeriği ve geliştirilmiş ısıl işlem teknolojisi sayesinde döngüsel yorgunluk açısından üstün performans sergilediği görülmüştür. Ayrıca, yüzey bütünlüğünün korunmasında da Scope UniBlue sisteminin daha avantajlı olduğu saptanmıştır. Bu bulgular, klinik kullanım açısından daha dayanıklı ve güvenli eğe sistemlerinin seçiminde yol gösterici olabilir. | |
| dc.description.abstract | Objective: The aim of this study was to comparatively evaluate the effects of different heat treatment protocols on the cyclic fatigue resistance and surface roughness of two nickel-titanium (NiTi) rotary file systems: Scope UniGold and Scope UniBlue. Additionally, the influence of the number of uses and sterilization procedures on these parameters was investigated. Materials and Methods: A total of 120 files were divided into four groups (n=12) (unused, used 1, 2 and 3 times), 96 of which belonged to Scope UniGold and Scope UniBlue systems. The file systems were subjected to cyclic fatigue testing at 37°C in 90° inclined stainless steel channels. In addition, the remaining 24 were divided into four groups (n=12) for surface roughness evaluation and SA (arithmetic mean roughness) and SZ (maximum peak-trough height) measurements were made with a contact profilometer. ANOVA, Mann-Whitney U and Kruskal-Wallis tests were used for statistical analysis. Results: The Scope UniBlue files exhibited significantly higher resistance to cyclic fatigue compared to the Scope UniGold files (p<0.001). An increase in the number of uses led to a notable decrease in fatigue resistance in both systems. Surface roughness evaluations revealed that repeated use increased surface irregularities, with Scope UniGold showing greater changes in Sa and Sz values after the second and third uses. Conclusion: Scope UniBlue files demonstrated superior performance in terms of cyclic fatigue resistance, likely due to their higher martensitic phase content and advanced heat treatment technology. Additionally, Scope UniBlue maintained better surface integrity over repeated uses. These findings may guide clinicians in selecting more durable and reliable file systems for safe endodontic treatment. | |
| dc.language.iso | tr | |
| dc.publisher | Afyonkarahisar Sağlık Bilimleri Üniversitesi | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Diş Hekimliği | |
| dc.subject | Dentistry | |
| dc.title | Farklı ısıl işlem görmüş eğe sistemlerinin tekrarlayan kullanımının yüzey pürüzlülüğü ve döngüsel yorgunluk direncine olan etkisi | |
| dc.title.alternative | Effect of repeated use of different heat-treated file systems on surface roughness and cyclic fatigue resistance | |
| dc.type | Specialist Thesis | |
| dc.department | AFSÜ, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalı | |
| dc.identifier.startpage | 1 | |
| dc.identifier.endpage | 112 | |
| dc.relation.publicationcategory | Tez | |
| dc.identifier.yoktezid | 967568 | |
| dc.snmz | KA_TEZ_20251227 | |