dc.contributor.author | Dülgeroğlu, Yakup | |
dc.contributor.author | Ercan, Müjgan | |
dc.date.accessioned | 2023-12-11T12:13:47Z | |
dc.date.available | 2023-12-11T12:13:47Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Dülgeroğlu, Y., & Ercan, M. (2023). Biological variation of serum neopterin concentrations in apparently healthy individuals. Clinical Chemistry and Laboratory Medicine (CCLM), (0). | en_US |
dc.identifier.issn | 1437-4331 | |
dc.identifier.uri | https://dx.doi.org/10.1515/cclm-2023-1030. | |
dc.identifier.uri | https://hdl.handle.net/20.500.12933/1822 | |
dc.description.abstract | Objectives: The aims of this study were to determine the biological variation (BV), reference change value (RCV), index of individuality (II), and quality specifications for serum neopterin concentrations; a measurand provided by clinical laboratories as an indicator of cellular immunity.
Methods: The study delivered serum samples collected for 10 consecutive weeks from 12 apparently healthy individuals (3 male, 9 female). Serum neopterin concentrations were measured using high-performance liquid chromatography with fluorometric detection. The data analysis was performed using an online statistical tool and addressed published criteria for estimation of biological variation.
Results: The mean neopterin concentration was 5.26 nmol/L. The within-subject biological variation (CVI) with 95 % confidence interval (CI) of neopterin serum concentrations was 11.54 % (9.98-13.59), and the between-subject biological variation (CVG) with 95 % CI was 43.27 % (30.52-73.67). The neopterin asymmetrical RCV was -24.9 %/+33.1 %, and the II was 0.27. The desirable quality specifications for neopterin were <5.77 % for precision, <11.20 % for bias, and <20.72 % for total allowable error (TEa). When analytical variation was used instead of CVI to calculate TEa, the desirable TEa was <18.39.
Conclusions: This study determined BV data for neopterin, an indicator of cell-mediated immune response. Asymmetric RCV values, of 24.9 % decrease or a 33.1 % increase between consecutive measurements indicate significant change. The II of 0.27 indicates a high degree of individuality, therefore that it is appropriate to consider the use of personal reference data and significance of change rather than the reference interval as points of reference for the evaluation of neopterin serum concentrations. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Walter De Gruyter | en_US |
dc.relation.isversionof | 10.1515/cclm-2023-1030. | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Biological Variation | en_US |
dc.subject | Index of Individuality | en_US |
dc.subject | Neopterin | en_US |
dc.subject | Reference Change Value | en_US |
dc.title | Biological variation of serum neopterin concentrations in apparently healthy individuals | en_US |
dc.type | article | en_US |
dc.authorid | 0000-0002-9291-4197 | en_US |
dc.department | AFSÜ, Tıp Fakültesi, Temel Tıp Bilimleri Bölümü, Tıbbi Biyokimya Ana Bilim Dalı | en_US |
dc.contributor.institutionauthor | Ercan, Müjgan | |
dc.relation.journal | Clinical chemistry and laboratory medicine | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |