Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCoşğun, İbrahim Güven
dc.contributor.authorGünay, Ersin
dc.contributor.authorÇilekar, Şule
dc.contributor.authorGünay, Sibel
dc.date.accessioned2023-10-24T06:53:46Z
dc.date.available2023-10-24T06:53:46Z
dc.date.issued2022en_US
dc.identifier.citationCoşgun, İ. G., Günay, E., Çilekar, Ş., & Günay, S. (2022). Efficacy of TBNA needles for EBUS during fiberoptic bronchoscopy?.en_US
dc.identifier.issn2791-6022
dc.identifier.urihttps://dx.doi.org/10.26900/hsq.2.3.04
dc.identifier.urihttps://hdl.handle.net/20.500.12933/1673
dc.description.abstractConventional transbronchial needle aspiration (cTBNA) biopsy is a diagnostic minimally invasive technique applied using fibreoptic bronchoscopy (FOB) in the evaluation of mediastinal/hilar lymph nodes. With the development of endobronchial ultrasound (EBUS) devices, transbronchial aspiration needles have been revised for use according to the EBUS guidelines. The main aim of this research was to evaluate the diagnostic success of transbronchial aspiration needles that was produced for EBUS when it was applied with FOB instead of conventional TBNA. A retrospective examination was made with the data of 35 patients applied with FOB TBNA, using needles specifically designed for EBUS and 36 patients with conventional TBNA (cTBNA group), for lung cancer staging or the diagnosis of mediastinal lymphadenopathy between November 2018 and November 2019. Seventy-two and sixty procedures performed on 71 patients were included in the study. Diagnostic efficiency for TBNA and cTBNA groups were 91.4% and 83.3%, respectively. Conventional TBNA is still acceptable when the low cost and ease of application are taken into consideration. In conclusion, improvement of current conventional TBNA needles similar to EBUS-TBNA needles for more efficient aspiration capacity could be the first stepto increasing the TBNA diagnostic yield. Nevertheless, further studies are needed to confirm our results.en_US
dc.language.isoengen_US
dc.publisherHolistence Publicationsen_US
dc.relation.isversionof10.26900/hsq.2.3.04en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectConventional Transbronchial Needle Aspirationen_US
dc.subjectEndobronchial Ultrasounden_US
dc.subjectFiberoptic Bronchoscopyen_US
dc.titleEfficacy of TBNA needles for EBUS during fiberoptic bronchoscopy?en_US
dc.typearticleen_US
dc.authorid0000-0001-7365-8098en_US
dc.departmentAFSÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Göğüs Hastalıkları Ana Bilim Dalıen_US
dc.contributor.institutionauthorCoşğun, İbrahim Güven
dc.contributor.institutionauthorÇilekar, Şule
dc.identifier.volume2en_US
dc.identifier.issue3en_US
dc.identifier.startpage149en_US
dc.identifier.endpage155en_US
dc.relation.journalHealth sciences quarterlyen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster