dc.contributor.author | Altıntepe Doğan, Suat Serhan | |
dc.contributor.author | Doğan, Özgür | |
dc.contributor.author | Doğan, Özge | |
dc.contributor.author | Altıntepe Başkurt, Nihan | |
dc.date.accessioned | 2023-08-25T13:39:25Z | |
dc.date.available | 2023-08-25T13:39:25Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Doğan, S. S. A., Doğan, Ö., Doğan, Ö., & Başkurt, N. A. (2023). Protective potential of different mouthguard thicknesses against perianaesthetic dental trauma: a patient specific-finite element study. Computer Methods in Biomechanics and Biomedical Engineering, 1-11. | en_US |
dc.identifier.issn | 1476-8259 | |
dc.identifier.uri | https://dx.doi.org/ 10.1080/10255842.2023.2247515. | |
dc.identifier.uri | https://hdl.handle.net/20.500.12933/1589 | |
dc.description.abstract | Perianaesthetic dental trauma is a common anaesthesia-related complication. Theprevious studies have shown a lack of knowledge regarding mouthguard usage and controversial results related to perianaesthetic dental trauma prevention. This study aimed to conduct a finite element analysis of the compressive and tensile stresses on the tooth-periodontal ligament-bone complex using custom-made mouthguards of different thicknesses and glass fibre splints to prevent perianaesthetic dental trauma. Custom-fitted ethylene-vinyl acetate mouthguards of two different thicknesses (2 and 3 mm) and glass fibre splint were modelled. A linear static finite element analysis was performed by applying a rigid Macintosh laryngoscope to the palatal surface of the maxillary central incisors at 150 N. The model without a mouthguard and glass fibre splint showed the highest stress values at the palatinal root surfaces during the impact. Increasing the mouthguard thickness significantly decreased the stress-strain values regardless of the presence of the glass fibre splint. Maximum stresses in the group using the 3 mm mouthguard were the lowest compared with the other groups. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Informa Healthcare | en_US |
dc.relation.isversionof | 10.1080/10255842.2023.2247515. | en_US |
dc.rights | info:eu-repo/semantics/embargoedAccess | en_US |
dc.subject | Mouthguard | en_US |
dc.subject | Dental Avulsion | en_US |
dc.subject | Endotracheal Intubation | en_US |
dc.subject | Finite Element Analysis | en_US |
dc.subject | Laryngoscopy | en_US |
dc.subject | Perianaesthetic Dental Trauma | en_US |
dc.title | Protective potential of different mouthguard thicknesses against perianaesthetic dental trauma: a patient specific-finite element study | en_US |
dc.type | article | en_US |
dc.authorid | 0000-0003-0215-7864 | en_US |
dc.department | AFSÜ | en_US |
dc.contributor.institutionauthor | Altıntepe Doğan, Suat Serhan | |
dc.contributor.institutionauthor | Doğan, Özgür | |
dc.relation.journal | Computer Methods in Biomechanics and Biomedical Engineering | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |