Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAltıntepe Doğan, Suat Serhan
dc.contributor.authorDoğan, Özgür
dc.contributor.authorDoğan, Özge
dc.contributor.authorAltıntepe Başkurt, Nihan
dc.date.accessioned2023-08-25T13:39:25Z
dc.date.available2023-08-25T13:39:25Z
dc.date.issued2023en_US
dc.identifier.citationDoğan, S. S. A., Doğan, Ö., Doğan, Ö., & Başkurt, N. A. (2023). Protective potential of different mouthguard thicknesses against perianaesthetic dental trauma: a patient specific-finite element study. Computer Methods in Biomechanics and Biomedical Engineering, 1-11.en_US
dc.identifier.issn1476-8259
dc.identifier.urihttps://dx.doi.org/ 10.1080/10255842.2023.2247515.
dc.identifier.urihttps://hdl.handle.net/20.500.12933/1589
dc.description.abstractPerianaesthetic dental trauma is a common anaesthesia-related complication. Theprevious studies have shown a lack of knowledge regarding mouthguard usage and controversial results related to perianaesthetic dental trauma prevention. This study aimed to conduct a finite element analysis of the compressive and tensile stresses on the tooth-periodontal ligament-bone complex using custom-made mouthguards of different thicknesses and glass fibre splints to prevent perianaesthetic dental trauma. Custom-fitted ethylene-vinyl acetate mouthguards of two different thicknesses (2 and 3 mm) and glass fibre splint were modelled. A linear static finite element analysis was performed by applying a rigid Macintosh laryngoscope to the palatal surface of the maxillary central incisors at 150 N. The model without a mouthguard and glass fibre splint showed the highest stress values at the palatinal root surfaces during the impact. Increasing the mouthguard thickness significantly decreased the stress-strain values regardless of the presence of the glass fibre splint. Maximum stresses in the group using the 3 mm mouthguard were the lowest compared with the other groups.en_US
dc.language.isoengen_US
dc.publisherInforma Healthcareen_US
dc.relation.isversionof10.1080/10255842.2023.2247515.en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectMouthguarden_US
dc.subjectDental Avulsionen_US
dc.subjectEndotracheal Intubationen_US
dc.subjectFinite Element Analysisen_US
dc.subjectLaryngoscopyen_US
dc.subjectPerianaesthetic Dental Traumaen_US
dc.titleProtective potential of different mouthguard thicknesses against perianaesthetic dental trauma: a patient specific-finite element studyen_US
dc.typearticleen_US
dc.authorid0000-0003-0215-7864en_US
dc.departmentAFSÜen_US
dc.contributor.institutionauthorAltıntepe Doğan, Suat Serhan
dc.contributor.institutionauthorDoğan, Özgür
dc.relation.journalComputer Methods in Biomechanics and Biomedical Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster