dc.description.abstract | Background and aim: The aim of this study is to evaluate the apical debris extrusion amounts and preparation times of four different nickel-titanium systems with a similar cross-section design-Mtwo, RECIPROC, RECIPROC blue, and VDW.ROTATE.
Materials and methods: Eighty human mandibular central incisors were divided into four equal groups (n = 20). The test apparatus was inserted into an assembly that provided root canal temperature. Preparation times were recorded using a stopwatch, and the amount of extruded debris was collected in pre-weighed Eppendorf tubes. After drying, the net amount was determined by subtracting the previously measured Eppendorf tube weights from the total weight.
Results: The Mtwo had the largest amount of debris, but there was no significant difference among the other groups. The VDW.ROTATE completed the preparation in a significantly shorter time than the RECIPROC blue and Mtwo.
Conclusion: Compared to other files, the Mtwo sequence produced significantly more debris and required significantly more time to complete the whole root canal preparation. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Medknow Publications | en_US |
dc.relation.isversionof | 10.4103/njcp.njcp_455_22. | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Blue Wire | en_US |
dc.subject | M-Wire | en_US |
dc.subject | Debris Extrusion | en_US |
dc.subject | Reciprocation | en_US |
dc.subject | Traditional Alloy | en_US |
dc.title | Comparison of apical debris extrusion of different generation nickel-titanium instrument systems | en_US |
dc.type | article | en_US |
dc.department | AFSÜ | en_US |
dc.contributor.institutionauthor | Uygun, A. D. | |
dc.identifier.volume | 25 | en_US |
dc.identifier.issue | 12 | en_US |
dc.identifier.startpage | 2010 | en_US |
dc.identifier.endpage | 2015 | en_US |
dc.relation.journal | Nigerian Journal of Clinical Practice | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |