Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDoğan, Mustafa
dc.contributor.authorAlizada, Anar
dc.contributor.authorNorman Özdamar, Esma
dc.contributor.authorSabaner, Mehmet Cem
dc.contributor.authorYazgan, Serpil
dc.contributor.authorKüsbeci, Tuncay
dc.date.accessioned2022-06-30T13:50:05Z
dc.date.available2022-06-30T13:50:05Z
dc.date.issued2020en_US
dc.identifier.citationDOGAN, M., ALIZADA, A., NORMAN OZDAMAR, E., SABANER, M. C., YAZGAN, S., & KUSBECI, T. (2020). Impact of Valsalva Maneuver on Central Corneal Thickness, Anterior Chamber, Macular, Optic Nerve Parameters and Choroidal Thickness in Pseudoexfoliation Glaucoma Patients. Glokom-Katarakt/Journal of Glaucoma-Cataract, 29(2).en_US
dc.identifier.issn2717-7157
dc.identifier.urihttps://doi.org/10.37844/glauc.cat.2020.15.19
dc.identifier.urihttps://hdl.handle.net/20.500.12933/1285
dc.description.abstractPurpose: To evaluate impact of Valsalva maneuver on central corneal thickness, anterior chamber parameters, optic nerve parameters and macular-choroidal thickness of pseudoexfoliation glaucoma (PEG) patients.Materials and Methods: Fifty-three eyes of 30 patients with PEG were included in this study between January 2017 and August 2017. All patients under went optic disc, retinal nerve fi ber layer (OD RNFL), central macular thickness (CMT) and subfoveal choroidal thickness (CT) measurements performed by Spectral Domain Optic CoherenceTomography (SD-OCT); irido corneal angle (ICA), anterior chamber depth(ACD), and central corneal thickness (CCT) measurements were performed with Sirius Scheimpfl ug-Placido Topographer before and during Valsalva maneuver (VM). Results: OD RNFL parameters were signifi cantly decreased during the VM (82.1±21.5 μm before VM, 81.6±21.2 μm during VM, p‹0.034). There were decrease in parameters of CMT (218.9±25 μm before VM, 217.5±24 μm during VM p=0.83), ICA (42.5°±9 before VM, 42.0°±9 during VM , p=0.188) and ACD (3.39±0.6 mm before VM, 3.38±0.6 mm during VM , p=0.082) but these impacts were not signifi cant. There was signifi cantly increase in parameters of subfoveal CT during VM (213.3±40.9 μm before and 224.0±40.0 μm during VM; p‹0.001 ). There was increase in parameters of CCT but this impactwas not significant (536.2±33.5 μm before VM , 537.5±35.8 μm during VM , p=0.237). Conclusions: The VM has some infl uence on corneal morphology and anterior chamber parameters, but they were not significant. The changes in RNFL and CT have to be in mind during patient examination due to thein fluence of VM.en_US
dc.language.isoengen_US
dc.publisherGazi Göz Vakfıen_US
dc.relation.isversionof10.37844/glauc.cat.2020.15.19en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPseudoexfoliationen_US
dc.subjectGlaucomaen_US
dc.subjectValsalvaen_US
dc.subjectChoroiden_US
dc.subjectCorneaen_US
dc.titleImpact of Valsalva Maneuver on Central Corneal Thickness, Anterior Chamber, Macular, Optic Nerve Parameters and Choroidal Thickness in Pseudoexfoliation Glaucoma Patientsen_US
dc.typearticleen_US
dc.authorid0000-0001-7237-9847en_US
dc.authorid0000-0002-0958-9961en_US
dc.departmentAFSÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.contributor.institutionauthorDoğan, Mustafa
dc.contributor.institutionauthorAlizada, Anar
dc.contributor.institutionauthorSabaner, Mehmet Cem
dc.identifier.volume29en_US
dc.identifier.issue2en_US
dc.identifier.startpage99en_US
dc.identifier.endpage105en_US
dc.relation.journalGlokom Katarakten_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster