Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorUğurlu, Berat Tuğrul
dc.contributor.authorTürk, Ali
dc.contributor.authorCelasun, Mustafa Gürol
dc.contributor.authorHekimoğlu, Azamat
dc.date.accessioned2022-05-17T12:24:34Z
dc.date.available2022-05-17T12:24:34Z
dc.date.issued01.05.2022en_US
dc.identifier.citationUğurlu, B. T., Türk, A., Celasun, M. G., & Hekimoglu, A. (2022). Fluence map analyzer reduces low dose volume in locally advanced post mastectomy breast cancer patients. Biomedical Physics & Engineering Express, 8(3), 035003.en_US
dc.identifier.issn2057-1976
dc.identifier.urihttps://doi.org/10.1088/2057-1976/ac584e
dc.identifier.urihttps://hdl.handle.net/20.500.12933/1031
dc.description.abstractMulti-leaf collimator dose leakage in intensity-modulated radiotherapy (IMRT) plans causes higher low dose volume which increases the long-term risks of radiotherapy. We have developed Fluence Map Analyzer (FMA) program that suggests the ideal field geometry to reduce low dose volume in locally advanced breast cancer IMRT plans. In this comparative experimental study, FMA has been applied to standard IMRT plans (STD-IMRT) of randomly selected 15 left and 15 right-sided locally advanced breast cancer patients. All patients underwent a modified radical mastectomy. The chest wall, IMN, axillary, and supraclavicular lymph nodes are included in planning target volume (PTV). The heart, lungs, contralateral breast, and medulla spinalis were delineated as organs at risk (OARs). Two sets of plans, namely STD-IMRT and FMA-IMRT, were generated for each patient. The dosimetric analysis was performed using dose-volume histogram (DVH) and standard evaluation parameters of PTV and OARs. No differences could be observed among the two techniques for PTV coverage. However, FMA-IMRT plans achieved significantly lower V5 volumes and mean doses of the heart, lungs, contralateral breast, and body contours. FMA-IMRT used a smaller number of sub-fields and fewer monitor units (MU). FMA automizes the field geometry determination process for locally advanced breast cancer IMRT planning while reducing low dose volume significantly.en_US
dc.language.isoengen_US
dc.publisherIOP Publishingen_US
dc.relation.isversionof10.1088/2057-1976/ac584een_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleFluence map analyzer reduces low dose volume in locally advanced post mastectomy breast cancer patientsen_US
dc.typearticleen_US
dc.authorid0000-0002-5232-3894en_US
dc.departmentAFSÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyasyon Onkolojisi Ana Bilim Dalıen_US
dc.contributor.institutionauthorHekimoğlu, Azamat
dc.identifier.volume8en_US
dc.identifier.issue3en_US
dc.relation.journalBiomedical Physics & Engineering Expressen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster