Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorTurhan, Mehmet Fatih
dc.date.accessioned2022-04-28T06:08:22Z
dc.date.available2022-04-28T06:08:22Z
dc.date.issued28.08.2021en_US
dc.identifier.citationTurhan, M. F. (2021). Photon interaction performance of various contrast agents: Theoretical and simulation results. Applied Radiation and Isotopes, 177, 109920.en_US
dc.identifier.issn0969-8043
dc.identifier.issn1872-9800
dc.identifier.urihttps://doi.org/10.1016/j.apradiso.2021.109920
dc.identifier.urihttps://hdl.handle.net/20.500.12933/848
dc.description.abstractIn this study, total mass attenuation coefficient (μ/ρ) values in the energy range from 60 keV to 15 MeV for some contrast agents (Iopamidol, Metrizamide, Iohexol, Ioxaglic acid, Iopromide, Ioversol and Iopentol) were deter- mined with the WinXCOM computer program and GEANT4 computer simulation code. Linear attenuation co- efficients (μ), half value layers (HVL), tenth value layers (TVL), mean free paths (mfp), effective atomic numbers (ZEff) and effective electron densities (NEff) in the aforementioned energy range were obtained with the help of the calculated total mass attenuation coefficients. Energy absorption build-up factors (EABF) and exposure build- up factors (EBF) for contrast agents were calculated using the five-parameter geometric progression (G-P) fitting method in the energy region of 0.015 MeV ≤ E ≤ 15 MeV for different penetration depths up to 40 mfp with the help of the equivalent atomic numbers (Zeqv). Kerma relative to air values were investigated in the energy region 0.001 MeV ≤ E ≤ 20 MeV. It has been observed that Ioxaglic acid is a good radiation absorber according to the other studied contrast agents. The present results may contribute to various application areas of radiation researchen_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.apradiso.2021.109920en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectContrast agenten_US
dc.subjectAttenuation coefficienten_US
dc.subjectEffective atomic numberen_US
dc.subjectKerma relative to airen_US
dc.subjectGamma-ray build-up factoren_US
dc.titlePhoton interaction performance of various contrast agents: Theoretical and simulation resultsen_US
dc.typearticleen_US
dc.authorid0000-0002-0676-9481en_US
dc.departmentAFSÜ, Bolvadin Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Hizmetler ve Teknikler Bölümüen_US
dc.contributor.institutionauthorTurhan, Mehmet Fatih
dc.identifier.volume177en_US
dc.identifier.startpage1en_US
dc.identifier.endpage14en_US
dc.relation.journalApplied Radiation and Isotopesen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster