Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖzcan, Erhan Cahit
dc.contributor.authorGül, Mehmet
dc.contributor.authorDündar, Serkan
dc.contributor.authorBozoğlan, Alihan
dc.contributor.authorKarasu, Necmettin
dc.contributor.authorBal, Ali
dc.contributor.authorGüneş, Nedim
dc.contributor.authorBingül, Muhammet Bahattin
dc.date.accessioned2022-04-26T13:35:29Z
dc.date.available2022-04-26T13:35:29Z
dc.date.issued17.07.2021en_US
dc.identifier.citationOzcan, E. C., Gul, M., Dundar, S., Bozoglan, A., Karasu, N., Bal, A., ... & Bingul, M. B. (2021). Effects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants. Journal of Oral Biology and Craniofacial Research, 11(4), 524-528.en_US
dc.identifier.issn2212-4268
dc.identifier.urihttps://doi.org/10.1016/j.jobcr.2021.07.008
dc.identifier.urihttps://hdl.handle.net/20.500.12933/836
dc.description.abstractObjective: Researchs of the effects of ankaferd blood stopper (ABS) on bone healing metabolism have revealed that it affects bone regeneration positively. The exact mechanism by which this positive effect on bone tissue metabolism is not known. The aim of this study is to biomechanic and biochemical analysis of the effects of the local ABS application on osseointegration of 3 different surfaced titanium implants. Material & Methods: Spraque dawley rats were divided machined surfaced (MS) (n ¼ 10), sandblasted and large acid grid (SLA) (n ¼ 10) and resorbable blast material (RBM) (n ¼ 10) surfaced implants. ABS applied locally during the surgical application of the titanium implant before insertion in bone sockets. After 4 weeks experimental period the rats sacrificed and implants with surrounding bone tissues were removed to reverse torque analysis (Newton), blood samples collected to biochemical analysis (ALP, calcium, P) Results: Biomechanic bone implant contact ratio detected higher in SLA surfaced implants compared with the RBM and controls (P < 0,05). Phosphor levels detected lower in RBM implant group compared with the controls and SLA (P < 0,05). Additionally; phosphor levels detected highly in controls compared with the RBM implants. Conclusion: According the biomechanical parameters ABS may be more effective in SLA and RBM surfaced implants when locally applied.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.jobcr.2021.07.008en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAnkaferd blood stopperen_US
dc.subjectOsseintegrationen_US
dc.subjectBone implant contacten_US
dc.subjectImplant surfacesen_US
dc.subjectBiomechanicen_US
dc.titleEffects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implantsen_US
dc.typearticleen_US
dc.authorid0000-0001-6513-0226en_US
dc.authorid0000-0002-5721-8778en_US
dc.authorid0000-0003-3944-1957en_US
dc.authorid0000-0003-3420-5816en_US
dc.authorid0000-0003-0388-5767en_US
dc.authorid0000-0001-5750-4224en_US
dc.authorid0000-0001-7160-1899en_US
dc.authorid0000-0002-6581-2363en_US
dc.departmentAFSÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Plastik Rekonstrüktif ve Estetik Cerrahien_US
dc.contributor.institutionauthorKarasu, Necmettin
dc.identifier.volume11en_US
dc.identifier.issue4en_US
dc.identifier.startpage524en_US
dc.identifier.endpage528en_US
dc.relation.journalJournal of Oral Biology and Craniofacial Researchen_US