Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKaya, İsmail
dc.contributor.authorŞahin, Meryem Cansu
dc.contributor.authorCingöz, İlker Deniz
dc.contributor.authorAydın, Nevin
dc.contributor.authorAtar, Murat
dc.contributor.authorKızmazoğlu, Ceren
dc.contributor.authorKavuncu, Salih
dc.contributor.authorAydın, Hasan Emre
dc.date.accessioned2021-05-05T22:11:54Z
dc.date.available2021-05-05T22:11:54Z
dc.date.issued2019
dc.identifier.issn1300-0144
dc.identifier.urihttps://doi.org/10.3906/sag-1901-184
dc.identifier.urihttps://hdl.handle.net/20.500.12933/227
dc.descriptionPubMed: 31121999en_US
dc.description2-s2.0-85069493172en_US
dc.description.abstractBackground/aim: Application fields of bone tissue engineering studies continue to expand. New biocompatible materials aimed to improve bone repairment and regeneration of implants are being discovered everyday by scientists, engineers, and surgeons. Our objective in this study is to combine polylactic acid which is a polymer with hydroxyapatite in the repairment of bone defects considering the increased need by medical application fields. Materials and methods: After 750 g of PLA with a diameter of 2.85 mm was granulated into minimum particles, these particles were homogenously mixed with hydroxyapatite prepared in laboratory environment. Using this mixture, HA-PLA filament with a diameter of 2.85 mm was prepared in the extrusion device in Kütahya Medical Sciences University Innovative Technology Laboratory. The temperature was 250 °C and the gearmotor speed was 9 rpm during extrusion. X-ray diffraction (XRD) analysis was made for crystal phase analyses of the produced hydroxyapatite powder, to determine the produced main phase and examine whether a minor phase occurred. Vickers microhardness test was applied on both samples to measure the endurance levels of the samples prepared with HAPLA filament. A loading force of 10 kg was applied on the samples for 10 s. Results: Hydroxyapatite peaks in XRD spectrum of the sample presented in figures are concordant with Joint Committee on Powder Diffraction Standards, JCPDS - File Card No. 01-075-9526 and no significant minor phase was observed. For both samples, hardness value was observed to increase between 3 and 5 mm. Conclusion: Surfacing hydroxyapatite on metallic materials is possible. By similar logic, to increase durability with low cost, characteristics of biomaterials can be improved with combinations such as hydroxyapatite PLA. Thus, we found that while these materials have usage limitations due to present disadvantages when used alone, it is possible to increase their efficiency and availability through different combinations. © TÜBİTAK.en_US
dc.language.isoengen_US
dc.publisherTurkiye Kliniklerien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBone tissue engineeringen_US
dc.subjectFilamentsen_US
dc.subjectHydroxyapatiteen_US
dc.subjectPLAen_US
dc.subjectThree dimensional printingen_US
dc.titleThree dimensional printing and biomaterials in the repairment of bone defects; hydroxyapatite pla filamentsen_US
dc.typearticleen_US
dc.departmentAFSÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Plastik Rekonstrüktif ve Estetik Cerrahi
dc.contributor.institutionauthorKavuncu, Salih
dc.identifier.doi10.3906/sag-1901-184
dc.identifier.volume49en_US
dc.identifier.issue3en_US
dc.identifier.startpage922en_US
dc.identifier.endpage927en_US
dc.relation.journalTurkish Journal of Medical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster