Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÜnal, Server
dc.contributor.authorAsutay, Hilal
dc.contributor.authorOzkır, Serhat Emre
dc.contributor.authorBiçer, Mehmet
dc.date.accessioned2023-11-15T13:13:15Z
dc.date.available2023-11-15T13:13:15Z
dc.date.issued2023en_US
dc.identifier.citationÜnal, S. M., Asutay, H. Ç., Özkir, S. E., & Biçer, M. (2023). Evaluation of Heat on the Teeth During Upper Lip Laser Epilation: Clinical Experiment. Turkiye Klinikleri. Dishekimligi Bilimleri Dergisi, 29(1), 131-138.en_US
dc.identifier.issn2146-8966
dc.identifier.urihttps://dx.doi.org/10.5336/dentalsci.2022-90918
dc.identifier.urihttps://hdl.handle.net/20.500.12933/1776
dc.description.abstractObjective: The temperature of adjacent tissues during epilation has long been the subject of research. However, there is no literature on the heat that occurs in the teeth during laser epilation of the upper lip. This study measured the increase in the heat of the teeth during upper lip laser epilation. Material and Methods: The study included 51 patients. Three heat measurement sensors were placed on the labial surface of the anterior teeth. Before starting the procedure, the first measurement was taken, and the maximum values were recorded as °C. After the procedure, a visual analog scale (VAS) was applied. Paired samples t-tests and one-way ANOVA (p<0.05) test were applied for the statistical analysis. Results: A statistically significant difference was determined between the maximum and initial heat in the 3 sensors (S1F 36±1.7, S1Max 40.8±2.3, S2F 36.3±0.9, S2Max 40.3±1.8, S3F 36.3±0.9, S3Max 40.7±2.9). No statistically significant difference was determined between the 3 sensors in the distribution of the maximum and initial heat (p>0.05). A statistically significant difference was determined regarding the distribution of VAS values in the teeth and lips (p<0.001). The pain felt in the upper lip (6±2) was significantly greater than the pain felt in the teeth (5±2) (p<0.001). Conclusion: The increase in heat during upper lip laser epilation can be said to be safe for the dental pulp. The sensitivity and pain experienced during the procedure are due to the heat increase. The use of a white-coloured appliance is recommended during upper lip laser epilation.en_US
dc.language.isoengen_US
dc.publisherTürkiye Klinikleri Yayınevien_US
dc.relation.isversionof10.5336/dentalsci.2022-90918en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEvaluation of heat on the teeth during upper lip laser epilation: Clinical experimenten_US
dc.typearticleen_US
dc.departmentAFSÜen_US
dc.contributor.institutionauthorÜnal, Server
dc.identifier.volume29en_US
dc.identifier.issue1en_US
dc.identifier.startpage131en_US
dc.identifier.endpage138en_US
dc.relation.journalTürkiye Klinikleri Diş Hekimliği Bilimleri Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster