Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorErdoğan, Y.
dc.contributor.authorKarayılmaz, H.
dc.contributor.authorÜnal, Mehmet
dc.contributor.authorGüngör, O.
dc.contributor.authorÇiftci, Z.
dc.date.accessioned2021-05-05T22:11:50Z
dc.date.available2021-05-05T22:11:50Z
dc.date.issued2020
dc.identifier.issn1119-3077
dc.identifier.urihttps://doi.org/10.4103/njcp.njcp_704_19
dc.identifier.urihttps://hdl.handle.net/20.500.12933/171
dc.descriptionPubMed: 32788488en_US
dc.description2-s2.0-85089613942en_US
dc.description.abstractBackground: Contamination is a common problem in pediatric restorative dentistry and there are a few studies that investigate blood contamination, hemostatic agents, and tooth dentin. Aim: The purpose of this study was to evaluate the effects of blood contamination and hemostatic agents on the bond strength of two different bonding systems with the dentin of primary teeth. Materials and Methods: Buccal and lingual dentin surfaces of 40 primary second molar teeth were used for this study. Specimens were divided into 4 groups according to the contamination and hemostatic agents (Blood-B, Ankaferd Blood Stopper-A, ViscoStat-V, Control-C) and then every group was further divided into two subgroups according to the bonding systems (Clearfil SE Bond-I, All Bond Universal-II, n = 10 per group). A bulk-fill composite resin was built-up on the surfaces. The specimens were tested in the micro shear mode at a crosshead speed of 1 mm/min on a universal test machine. Statistical analysis was performed with ANOVA and Tukey's tests at P < 0.05. Results: Significant differences have been detected in the micro shear bond strengths only between the Ankaferd Blood Stopper (ABS) (AI = 13.72 ± 4.47 and AII = 9.12 ± 4.4) and control groups (CI = 22.78 ± 10.86 and CII = 16.49 ± 6.55) without regards to the bonding systems. The highest scores were obtained in the control groups. Clearfil SE Bond showed better performance than All Bond Universal in all groups. Conclusion: It was determined that only the ABS contamination groups showed statistically significant decreases in the bond strengths when compared with control groups. © 2020 Wolters Kluwer Medknow Publications. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBlood contaminationen_US
dc.subjectbond strengthen_US
dc.subjectdentinen_US
dc.subjecthemostatic agentsen_US
dc.subjectprimary teethen_US
dc.titleEffects of Blood Contamination and Hemostatic Agents on Bond Strength in Primary Teeth Dentinen_US
dc.typearticleen_US
dc.departmentAFSÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.contributor.institutionauthorÜnal, Mehmet
dc.identifier.doi10.4103/njcp.njcp_704_19
dc.identifier.volume23en_US
dc.identifier.issue8en_US
dc.identifier.startpage1103en_US
dc.identifier.endpage1109en_US
dc.relation.journalNigerian Journal of Clinical Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster